Subject description - BEAM38KLS
Summary of Study |
Summary of Branches |
All Subject Groups |
All Subjects |
List of Roles |
Explanatory Notes
Instructions
BEAM38KLS | Construction of Medical Systems | ||
---|---|---|---|
Roles: | PV, PS | Extent of teaching: | 2P+2L |
Department: | 13138 | Language of teaching: | EN |
Guarantors: | Holub J. | Completion: | Z,ZK |
Lecturers: | Holub J. | Credits: | 6 |
Tutors: | Holub J. | Semester: | Z |
Anotation:
General principles and design and construction of medical devices and systems. Technical standards and requirements for the design, construction and operation of medical electrical appliances. Classification classes of instruments. Electromagnetic Compatibility of Medical Devices. Modern component base. Design and construction of basic blocks of medical devices.Course outlines:
1. | Technical standards requirements, general structure of the medical device, instrument classes, parameters and design process | |
2. | Modern component base, features, selection and application recommendations | |
3. | Design and construction of basic electronic functional blocks of medical devices | |
4. | Measurement amplifiers | |
5. | Measurement converters | |
6. | Electromagnetic Compatibility of Medical Devices | |
7. | Power circuits, interconnection, cables and connections, parasitic links and transmissions, shielding, interference methods | |
8. | Interconnection of analog device blocks - signal levels, linearity, interference. Switching and coupling circuits | |
9. | Advanced analog-to-digital conversion methods, circuits | |
10. | Digital-analog converters, signal reconstruction | |
11. | Mechanical design, design, cooling and instrumentation | |
12. | Systems for computer support of design of measuring instruments, virtual measuring devices | |
13. | Summary, conclusions | |
14. | Spare |
Exercises outline:
Laboratory exercises:1. | Methods of galvanic separation used in medical devices | |
2. | Analogue filters for biosignals, design, implementation and measurement | |
3. | Suppression of consistent interference with amplifiers | |
4. | Suppression of alternating interference in analogue and digital circuits | |
5. | Medium and Effective Value Converters, Nonlinear Amplifiers. | |
6. | Frequency signal filtration, filters with switched capacitors | |
7. | Insulating amplifier | |
8. | Project assignment - Design of the block of the measuring instrument, verification of the model, comparison with the parameters of the professional device | |
9. | Project solution - design | |
10. | Project - model I 11. Project - model II | |
12. | Project - comparison of parameters with professional solutions | |
13. | Evaluation of results | |
14. | Assessment |
Literature:
[1] | Kimmel, W.D., Gerke, D.D.: Electromagnetic Compatibility in Medical Equipment. Piscataway: IEEE Press. 1995 |
Requirements:
Subject is included into these academic programs:Program | Branch | Role | Recommended semester |
MEBIO4_2018 | Signal Processing | PV | 3 |
MEBIO3_2018 | Image Processing | PV | 3 |
MEBIO1_2018 | Bioinformatics | PV | 3 |
MEBIO2_2018 | Medical Instrumentation | PS | 3 |
Page updated 14.10.2024 17:51:34, semester: Z/2025-6, Z,L/2024-5, L/2023-4, Send comments about the content to the Administrators of the Academic Programs | Proposal and Realization: I. Halaška (K336), J. Novák (K336) |